The Clinical Application Value of CT Guided Bard Magnum Puncture Cutting Needle in Pulmonary Hilum Mass Biopsy
LI Xiao-guang
ZHU Hai-tao
Abstract:Objective:To investigate the clinical application value and complications prevention of CT guided percutaneous pulmonary hilum puncture biopsy.Method:35 cases with pulmonary hilum occupying lesions,underwent CT guided percutaneous lung puncture biopsy,because bronchoscopic biopsy and brush biopsy(TBLB+BB) were negative,the positive rate,the occurrence,prevention and treatment measures of complication were analysed.Result:In 35 cases, the positive rate of successful puncture was 88.6%(31/35),the main complications were pneumothorax(5 cases),pulmonary hemorrhage (3 cases),pleura reaction (1 case).Conclusion:CT guided percutaneous pulmonary hilum puncture biopsy has higher diagnosis rate,less complications,security is relatively high,it is a safe and effective minimally invasive diagnostic techniques for bronchoscopic biopsy and brush biopsy (TBLB+BB) negative pulmonary hilar occupying cases.
Keywords:CT guidedPuncture cuttingBiopsy
Publication Date:2014-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:2( 59-59,60 )