Effects of two scanning methods on image quality and radiation dose in CT coronary angiography
Li Hongmei
Hua Li
Zhang Caihui
Zhang Shan
Zhang Jiqing
Zhang Yueying
Abstract:Objective To investigate the effects of prospective electrocardiographic(ECG) gated scanning and retrospective ECG gated scanning on image quality and radiation dose in CT coronary angiography (CTCA).Methods A total of 180 patients undergoing CTCA examination from March to December 2016 in Second Hospital of Shanxi Medical University were randomly divided into group A(92 cases) and group B (88 cases).Group A had prospective ECG gated cardiac scanning and group B had retrospective ECG gated scanning.Image quality and radiation dose were evaluated.Results Gender,age,body mass index and pre-scanning heart rate were similar between groups(all P >0.05).Heart rate and heart rate variability during scanning in group B were significantly higher than those in group A(P <0.01).With image quality score≥3 used as the judging standard,there was no significant difference of the percentage of coronary artery segments available for diagnosis between groups (x2 =1.37,P > 0.05).Using image quality score ≥ 2 as the standard,group B showed higher quality of images that could be used for specific diagnosis than group A [93.4% (674/722) vs 97.4% (835/857)] (x2 =15.42,P < 0.05).Effective radiation dose in group B was significantly higher than that in group A [(6.9 ± 0.6) mSv vs (2.3 ± 0.6) mSv] (P < 0.0l).Conclusion With an appropriate range of heart rate (< 70 beats/min),using prospective ECG gated scanning of CTCA can obtain high-quality image and reduce radiation dose.
Keywords:Coronary artery diseaseComputed angiographyImage qualityRadiation dose
Publication Date:2019-01-01
Online Publishing Date:2026-09-14(First online date of this platform, not the publication date of the document)
Pages:4( 334-337 )