Comparison of renal artery stenosis diagnosis by dynamic contrast enhanced magnetic resonance angiography and spiral computed tomography angiography
PAN Guang-xin
WANG Ping
GUO He-qing
SONG Yun-long
LIU Hong-ming
Abstract:Objective To evaluate the value of three dimensional dynamic contrast enhanced magnetic resonance angiography (DCE-MRA) and spiral CT angiography (SCTA) in the diagnosis of renal artery stenosis (RAS).Methods Fifty patients suspected of RAS were performed with both DCE-MRA and SCTA,and 25 patients confirmed with RAS were performed with DSA.Results DCE-MRA and SCTA in evaluation of RAS had the kappa coefficient of 0.831.In the diagnosis RAS,the sensitivity,specificity,positive and predictive value and negative predictive value of DCF-MRA (96.0%,94.0%,91.8%,98.0%) were slightly lower than those of SCTA(96.8%,95.7%,93.4%,96.7%).Conclusions DCE-MRA and CTA can accurately diagnose renal artery stenosis.ACEMRA is more safe and more appropriate for the diagnosis of the RAS compared with DCE-MRA.
Keywords:Renal artery stenosisDynamic contrast enhanced magnetic resonance angiographySpiral CT angiography
Publication Date:2013-01-01
Online Publishing Date:2026-09-14(First online date of this platform, not the publication date of the document)
Pages:3( 1747-1749 )