A Pilot Study on Dynamic Changes of EABR after Cochlear Implant
Tao Pan
Wang Yu
Lu Zhaoyi
Wang Zijian
Ma Furong
Abstract: Objective To study dynamic changes in electrically evoked auditory brainstem response (EABR) fol-lowing cochlear implant and to study auditory pathway response characteristics in response to chronic electrical stimu-lation for the purpose of providing a research foundation for studying auditory pathway plasticity. Methods With a prospective design, 20 prelingual children aged 3.2±1.0 years received intro-operative EABR measurement after insert-ing the cochlear implant electrode. EABR measurement was repeated at 5.4±3.2 months after cochlear implant. EABR threshold, latencies of waves III and V and input-output function were analyzed. Results EABR threshold decreased from 196.9±11.1 CL intro-operatively to 189.2±13.2CL CL at 5.4±3.2 months after cochlear implant. Paired t test showed significant change (p=0.006). The wave V latency decreased from 4.72±0.21 ms intro-operatively to 4.60± 0.18 ms at 5.4±3.2 months after cochlear implant (p=0.032). Conclusion Changes in EBAR threshold and latency are already evident at 5.4±3.2 months following cochlear implant. This indicates excellent auditory pathway plasticity in children around 3 years of age and the importance of early auditory training and speech habilitation after cochle-ar implant.
Keywords:Cochlear implantEABRplasticitychildren
Publication Date:2013-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:5( 200-204 )
Chinese Journal of Otology

Chinese Journal of Otology

PKUISTIC
ISSN:1672-2922
Year, Vol.(Issue):2013,(2)