Research on Lighting Harmonic Control of High Voltage Capacitor Complete Equipment
TANG You
Abstract:A 110 kV substation high-voltage capacitor bank set experienced serious harmonic pollution during operation.Harmonic currents generated by LED lighting equipment caused the device to overheat,produce noise,and reduce the power factor.By analyzing the load characteristics of LED lighting equipment using harmonic source identification detection technology,studying the harmonic propagation mechanism with device harmonic response analysis technology,and designing a mitigation plan using LC filter compensation technology,a systematic harmonic mitigation project was implemented.
Keywords:complete set of high-voltage capacitor equipmentharmonic controlLC filtering compensationharmonic detectionpower quality
Publication Date:2026-02-25
Online Publishing Date:2026-03-12(First online date of this platform, not the publication date of the document)
Pages:3( 84-86 )
China Light & Lighting

China Light & Lighting

ISSN:1002-6150
Year, Vol.(Issue):2026,(2)