Effect of Different Placement Methods on CDNE Radiated Disturbance of Split Metal Panel Luminaire
HU Jiangliang
CAI Jinbiao
LIU Qiong
SI Junchu
JIN Meiling
Abstract:According to the verification,the test results are quite different based on different setting position of controlgear when the Split metal panel light luminaire is applying the CDNE Radiated disturbance.If the engineers of enterprise laboratories or third-party testing institutions do not take into account the impact of such differences on the test results when testing such products,it will lead to the possibility of misjudgment of the products.The essay is to illustrate the perspective by actual examination and convey some references for those people who are getting involved in the testing of CDNE Radiated disturbance for these kind of products.
Keywords:CDNEradiated disturbancesplit metal panelcontrolgearsetting position
Publication Date:2024-12-25
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 46-48,156 )
China Light & Lighting

China Light & Lighting

ISSN:1002-6150
Year, Vol.(Issue):2024,(12)