The Key Points on Measuring and Verifying the Data Consistency on Lamp Energy Efficiency
Abstract:To ensure the better consistency of test results, some factors such as effective control of temperature, requirement for standard lamp, selection of integrating sphere, rational use of reference ballast, the lamp operating position and the control of testing time should be specially concerned during the test for verifying energy efficiency data consistency of high pressure sodium lamp and self-ballasted fluorescent lamp.
Keywords:data consistency verificationtemperature controlstandard lampintegrating spherereference ballasttest time