Exploration on the clinical application value of optimization of magnetic resonance gradient echo T?2weighted imaging sequence parameters in patients with acute ischemic stroke
LI Yanhua
YANG Weizhen
CHEN Peng
LI Ruixiong
YAN Yejing
WANG Tianzhao
Abstract:Objective To explore the clinical application value of optimization of magnetic resonance gradient echo T?2 weighted imaging(GRE-T?2 WI)sequence parameters in patients with acute ischemic stroke(AIS).Methods A total of 50 AIS patients were selected from the People's Hospital of Wuzhou during June 2017 and December 2018,including 38 males and 12 females,aged 41 to 92(65.50±5.90)years.GRE-T?2 WI examination was performed on each patient using four parameters,and four groups of images were obtained.Group A was the control group,and group B had the reduced matrix,number of excitation(NEX)and time of repetition(TR)on the basis of group A,and group C adopted parallel acquisition technique and had the reduced NEX,TR and echo time(TE)on the basis of group B,and group D had the further reduced TR,TE and matrix on the basis of group C.The scanning time,image quality score,signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)of the images were compared among the four groups.Results The scanning time in group A,group B,group C and group D was 81 seconds,40 seconds,15 seconds and 11 seconds,respectively.There were significant differences in the image quality scores,SNR and CNR of the parameters among the four groups(P<0.05).The image quality scores in group A,group B,group C and group D were(3.56±0.28)points,(3.34±0.34)points,(3.00±0.32)points and(1.68±0.40)points,respectively.There were significant differences in the image quality scores between group C and group D(P<0.05).There were no significant differences in the image quality scores between group C and group A as well as between group C and group B(P>0.05).Group D had the highest level of SNR,and there were significant differences in the levels of SNR between group C and group A as well as between group C and group B(P<0.05).There was no significant difference in the level of SNR between group C and group D(P>0.05).Group C had the highest level of CNR,and there were no significant differences in the levels of CNR between group C and group A as well as between group C and group D(P>0.05).There was significant difference in the level of CNR between group C and group B(P<0.05).Conclusion After adopting parallel acquisition technique and appropriately reducing matrix NEX,TR and TE parameters,the scanning time of GRE-T?2 WI is significantly short-ened,and its image quality meets the diagnostic requirements,which has great application value in the diagnosis and treatment of AIS patients.
Keywords:Acute ischemic stroke(AIS)Magnetic resonanceGradient echo T∗2 weighted imaging(GRE-T∗2 WI)Parameter optimizationImage quality
Publication Date:2024-03-28
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:5( 328-332 )
Chinese Journal of New Clinical Medicine

Chinese Journal of New Clinical Medicine

ISTIC
ISSN:1674-3806
Year, Vol.(Issue):2024,17(3)