Application and evaluation of the new automatic monitoring module and octreotide-induced hypoglycemia
ZHAO Su-yu
TANG Zhi-hui
GUO Dai-hong
ZHAO Liang
ZHU Man
MA Liang
ZHAO Peng-zhi
Abstract:[AbstrAct]Objective: To investigate the hypoglycemia induced by octreotide acetate injection, evaluate the performance of hypoglycemia module.Methods:The retrospective analysis was used to do automatic monitoring on inpatients using of octreotide acetate injection from January to June in 2016 detected by the intelligence assessment warning system for ADE. We manual screened the cases which selected by system, and analyzed the monitoring data.results:A total of 950 cases using octreotide acetate injection were automatically monitored. There were 26 cases of automatic alarm, in which 12 cases were positive by artiifcial evaluation. The incidence rate of adverse drug reactions was between 1.26%– 1.56%, which was in conformity with the speciifcation. People with pancreatic disease had the risk factors for hypoglycemia.conclusion: Hypoglycemia induced by octreotide is common, and patient's blood glucose levels should be monitored closely; hypoglycemia module can accurately relfect the real situation of ADR in clinical and make sure of drug safety.
Keywords:OctreotideHypoglycemiaAdverse drug reactionAutomatic monitoring
Publication Date:2016-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:3( 309-311 )

ISTIC
ISSN:1672-8157
Year, Vol.(Issue):2016,13(5)