Application of real-time three-dimensional transesophageal echocardiography in mitral valve prolapsed associated with infective endocarditis
LIU Le
ZHANG Xiao-ming
Abstract:Objective To evaluate the clinical value of real-time three-dimensional transesophageal echocardiography in mitral valve prolapse associated with infective endocarditis.Methods 20 patients undergoing mitral valve prolapse combined with IE were selected to undergo transthoracic echocardiography(TTE) and RT-3D-TEE.The prolapse position and performance characteristics were analyzed and intraoperative findings were compared.Results (1)The sensitivity of RT-3D-TEE and TTE in mitral valve prolapse was 90.3% and 87.1%,the specificity was 97.8% and 97.8%,the positive predictive value was 93.3% and 93.1%,the negative predictive value was 96.7% and 95.6%,The total compliance rate was 95.8% and 95%,RT-3D-TEE parameters were higher than TTE.(2)The diagnostic sensitivity and specificity of RT-3D-TEE in mitral valve formation,chordae rupture and perforation were higher than those in TTE.Conclusion (1)RT-3D-TEE is more accurate than TTE in locating the location of mitral valve prolapse.(2)RT-3D-TEE can accurately display the various manifestations of IE,and it is an important guide to the choice of preoperative surgical methods.
Keywords:Real-time three-dimensional transesophageal echocardiographyMitral valve prolapseInfective endocarditis
Publication Date:2017-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 815-817,后插1 )
Chinese Journal of Cardiovascular Research

Chinese Journal of Cardiovascular Research

ISTIC
ISSN:1672-5301
Year, Vol.(Issue):2017,15(9)