Robotic-assisted repair of esophageal hiatal hernia combined with fundoplication:A report of two cases
Abstract:Objective To evaluate the clinical safety and effectivity of da Vinci Si surgery system in repair of esophageal hiatal hernia combined with fundoplication.Methods Robotic-assisted repair of esophageal hiatal hernia combined with fundoplication was performed for two patients in our hospital on March, 2015. Results Repair of esophageal hiatal hernia combined with fundoplication was successfully performed by da Vinci Si surgery system in two patients. There were no operation related complications and without conversions to open surgery. The mean intraoperative blood loss was 25-30 mL. The mean operation time was 175 min. The first flatus and oral feeding were 44 h and 21 h after operation, respectively. Symptoms of the 2 patients were relieved completely.Conclusion Robotic-assisted repair of esophageal hiatal hernia combined with fundoplication is safe, effective. There are certain advantages in terms of suture.
Keywords:Robotic surgeryda Vinci Si surgery systemesophageal hiatal herniafundoplication
Publication Date:2015-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:3( 519-521 )