Application of intraoperative neromonitoring during complex thyroid operation
Abstract:Objective Apply the intraoperative neuromonitoring (IONM) as an adjunct to avoid recurrent laryngeal nerve (RLN) injury during complex thyroid operation. Methods From March 2009 to July 2009, 132 pations (186 nerves at risk) underwent complex thyroidectomy with the application of IONM. Vagus nerve and RLN were tested respectively before and after resection of thyroid lobe. Video recording of cord mobility was performed routinely pre- and postoperatively. Results In addition to 4 cases with preoperative vocal cord paralysis, 182 RLN after resection of thyroid lobe with a clear electromyography (EMG) and 0% nerves experienced signal loss before closing surgical incision. showed normal electrical transduction function. Accurately detect non-RLN in 2 nerves. Conclusion IONM could make RLN identification more reliabe and precise, test the functional integrity of RLN. IONM is a useful adjunct to reduce RLN palsy rate in complex thyroid operation.
Keywords:intraoperative neuromonitoringrecurrent laryngeal nervethyroid operationelectromyography
Publication Date:2010-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:3( 66-68 )
CHINESE JOURNAL OF PRACTICAL SURGERY

CHINESE JOURNAL OF PRACTICAL SURGERY

PKUISTIC
ISSN:1005-2208
Year, Vol.(Issue):2010,30(1)