Impact of Stimulation Parameters on Event-related Potential P300
MAO Chun-yan
SUN Li
YUAN Yuan
Abstract:Objective To observe the latency and amplitude characteristics of event-related potential P300 under different target stimu-lus. Methods During January to December, 2014, 35 patients with memory impairment received P300 test under the percentage of target stimuli of 0.10 and 0.25. The latency, amplitude and area under amplitude were compared. Results There was no significant difference in la-tency (t<0.256, P>0.800), but the amplitude and area under amplitude increased under 0.10 compared with those under 0.25 (t>4.259, P<0.05). Conclusion Less target stimulation may improve the patients' attention and increase amplitude of P300, but no more interference in la-tency, suggesting latency of P300 is more stable for assessment of cognitive function.
Keywords:stimulation parameterstarget stimuli percentageevent-related potentialP300latencyamplitudearea under amplitude
Publication Date:2016-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:3( 821-823 )

PKUISTIC
ISSN:1006-9771
Year, Vol.(Issue):2016,22(7)