Development and Validation of Finite Element Model of Young Normal Lower Cervical Spine
Abstract: Objective To develop and validate an anatomic detailed finite element model of the lower cervical spine. Methods The fi-nite element model of C4-C5-C6 was constructed using lower cervical spine (C4-C5-C6) CT images of a young healthy man. This model was validated against the standard deviation corridors of experimental data for normal, nondegenerated cervical spines tested in flexion and ex-tension, right and left lateral bending, and right and left axial rotation under physiological loading. Percent of load range deviation was intro-duced to measure the deviation of the model from the standard deviation corridors of experimental data. Results and Conclusion A finite el-ement model of young normal lower cervical spine has been developed and validated. The average percentage of load range was within 90%of standard deviation corridor.
Keywords:cervical spinefinite element analysisbiomechanics
Publication Date:2013-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 631-634 )