Constrast of PM2.5 test methods and emissions characterization research for coal-fired power plant
LIU Hanxiao
YAO Yuping
LI Jianguo
DING Honglei
CHANG Qianyun
ZUO Penglai
Abstract:According to the DL/T 1520-2016,the PM-10 (Dekati PM-10 Impactor,30 L/min),DGI (Dekati Gravimetric Impactor,70 L/min) and ELPI (Electrical Low Pressure Impactor,10 L/min) were used to carry out the field contrast test for coal-fired power plants.Based on field observations and literature research,the preliminary characterization of PM2.5 emissions in coal-fired power plant was summarized.The results show that the same instrument datum in the different periods and different instrument datum in the same time are all better repeatability and accuracy.
Keywords:fine particulate matter PM2.5coal-fired emissionsPM-10 impactorgravimetric impactorelectrical low pressure impactor
Publication Date:2017-01-01
Online Publishing Date:2026-05-22(First online date of this platform, not the publication date of the document)
Pages:6( 43-48 )