Research Design and Fault Countermeasures of Rotary Drum Ash Cooler
LIU Baiqian
Abstract:This paper reviews the major findings and technical errors occurred during the development of rotary drum ash cooler .It focuses mainly on the design criterions for key parameters based on the labora‐tory study and industrial practice and proposes the countermeasures in the event of faults .
Keywords:rotary drumdrained ashwaste heatcirculating fluidized bed boiler
Publication Date:2015-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:8( 7-14 )