Mechanical performance of ultra-low energy thin-walled exterior wall panels under single-sided heating
YAO Zhi
ZHANG Yunguang
NI Jingbo
ZENG Jincheng
HUANG Junqi
FENG Yulong
Abstract:This study employs finite element simulation to establish numerical models of ultra-low energy consumption thin-walled exterior wall panels and shear wall exterior panels.The mechanical performance of both panels under combined single-sided heating and wind loads was investigated.Results demonstrate that thin-walled panels exhibit greater susceptibility to temperature differences.The initial stiffness of wall panels shows a negative correlation with temperature differences caused by single-sided heating.Specifically,as the temperature difference increases from 10℃to 40℃,the initial stiffness decreases by approximately 61.47%-82.84%.Under identical temperature conditions,reducing the sandwich insulation layer thickness from 100 mm to 50 mm leads to a 41.85%reduction in initial stiffness and performance degradation.Changing the connector spacing from 500 mm to 300 mm does not significantly impact mechanical performance.
Keywords:single-sided heatinginner-outer surface temperature differencethin-walled exterior wall panelsshear wall exteri-or panelsmechanical performance
Publication Date:2025-11-25
Online Publishing Date:2025-12-15(First online date of this platform, not the publication date of the document)
Pages:6( 23-27,56 )