Experimental study on compatibility of composite waterproof layer
LAN Tianrui
LI Junde
LUO Xingye
Abstract:According to the national standard GB 55030-2022"General code for waterproofing of building and municipal engi-neering",the waterproofing practice for first-class waterproofing requires a minimum of 3 layers,with at least 2 layers dedicated to external waterproofing.The conventional approach in waterproof design and construction involves utilizing composite waterproof lay-ers to achieve the desired level of water resistance.This paper combines various commonly used waterproof materials in architec-tural and municipal engineering applications,analyzing the compatibility between these composite waterproof layers based on bond strength and damage patterns.This analysis provides a basis for material selection during the design and construction of composite waterproof layers.The results show that the non-curing rubber asphalt waterproof coating has good composite effect with modified asphalt waterproof coating and PVC waterproof coating.
Keywords:composite waterproof layercompatibilitywaterproof systempositive tensile bond strength
Publication Date:2024-07-25
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 96-98,102 )
New Building Materials

New Building Materials

ISTIC
ISSN:1001-702X
Year, Vol.(Issue):2024,51(7)