Simulation analysis of the thermal insulation performance of high reflectance and high shading built-in louver insulating glass
CHEN Wenjie
DONG Ze
FENG Mandi
XU Haihua
LI Jie
Abstract:This study employs WINDOW7 software to investigate the impact of louver solar reflectance and louver angle on the solar heat gain coefficient(SHGC)of electrically controlled built-in louver insulating glass and magnetically controlled built-in louver insulating glass with three panes and two cavities.The results indicate that with increasing louver angle and higher louver solar reflectance,the SHGC of both electrically controlled and magnetically controlled built-in louver insulating glass decreases.The minimum SHGC for electrically controlled built-in louver insulating glass is 0.108,meeting the requirements of the GB/T 51350-2019"Technical Standard for Nearly Zero Energy Buildings",which specifies a summer SHGC≤0.15.When the electric built-in louver insulating glass is used in near-zero energy consumption buildings,silver paint louvers or heat reflective paint louvers can be selected,and the solar heat gain coefficient can meet the application requirements of near-zero energy consumption buildings with high shielding blinds.
Keywords:built-in louver insulating glassthe solar heat gain coefficientlouver solar reflectancelouver angle
Publication Date:2024-07-25
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 81-84 )