Research and design of non-radioactive ash meter with multiple γ-ray detectors
BAI Yunfei
CHEN Peng
GE Zheng
ZHANG Guangchao
Abstract:To address the limitations of non-radioactive meter with single γ-ray detectors—including inad-equate counting rates for low natural radioactivity coal ash measurement,inability to cover the full cross section of wide conveyor belts,and susceptibility to environmental background fluctuations—a non-radioactive meter with multiple γ-ray detector is developed to enhance system performance and applicability.A 2 L NaI(Tl)scin-tillation detector is selected as the core detection component;each unit can be configured with up to 4 main de-tectors and 1 environmental background detector.The main detectors are flexibly arranged in transverse linear arrays or longitudinal area arrays,while the environmental detector is used to compensate for background inter-ference.Transverse linear arrays cover 1 800~2 200 mm bandwidth,and longitudinal area arrays extend the measurement zone.TEC semiconductor temperature control technology ensures detector temperature fluctu-ations remain below 0.5℃ within 24 hours.Dynamic regulation of high-voltage power supply improves the sta-bility of the non-radioactive meter,stabilizing the 1 460 keV characteristic energy peak around channel 256 in the multi-channel spectrum.Comparative single/double-detector tests are conducted on low-radioactivity coal samples from Eastern Inner Mongolia,and measurement resolution,precision,and long-term stability evalu-ations are performed on clean coal samples from Guangwang Mining Area.Results indicate that compared with single detector systems,dual detector meters achieve effective measurements.For low-radioactivity coal samples,the counting rate of dual detectors is approximately twice that of single detectors,the random error is reduced to 70%.In clean coal measurements,the unit load counting rate is 0.75 cps,with a 5.4 cps increase per 1%ash content rise.Measurement precision reaches 0.19%,and linear correlation(R2)is 0.96.Regarding long-term stability,the range of 24-hour continuous measurements is lower than 0.18%,fully meeting on-site applica-tion requirements.By enhancing counting rates,expanding detection coverage,and optimizing environmental compensation,the non-radioactive meter with multiple γ-ray detectors satisfies measurement demands for low-radioactivity coal and high-precision clean coal,demonstrating significant performance advantages and consider-able market potential with promising application prospects.
Keywords:non-radioactive metermulti γ-ray detectorcounting ratemeasurement resolutionmeasurement precisionlong-term stability
Publication Date:2025-06-30
Online Publishing Date:2025-09-30(First online date of this platform, not the publication date of the document)
Pages:7( 85-91 )
Goal Preparation Technology

Goal Preparation Technology

ISSN:1001-3571
Year, Vol.(Issue):2025,53(3)