A novel domestic-made stent-graft in endovascular abdominal aortic aneurysm repair:outcome of short- and medium-term follow-up and experience summary of a single-center controlled clinical trial
Liu Ming-yuan
Liu Bing
Wang Hao-fu
Abstract:BACKGROUND:Limited by the high financial burden of stent-graft and proof of evident-based medicine, the popularization of endovascular abdominal aortic aneurysm repair, a mini-invasive method, is impeded in China. In order to reduce costs, development of domestic-made stents is imperative, but the relative research is stil rare. OBJECTIVE:To compare the effect of domestic-made stent-graft (Percutek) and Gore Excluder in the endovascular abdominal aortic aneurysm repair. METHODS: From January to November 2014, there were 32 male patients with infrarenal abdominal aortic aneurysm, aged 56-79 years old with mean age of (70.2±6.9) years, admitted in the Vascular Surgery Department of the Affiliated Hospital of Qingdao University. Clinical data were colected and retrospectively analyzed. There were 11 cases undergoing domestic-made stent-graft repair and 21 undergoing Gore Excluder repair. Aortic CT angiography was performed at 1 and 6 months after surgery, and every 6 months thereafter to evaluate the effect of the two modalities. RESULTS AND CONCLUSION: Domestic-made stent-grafts were successfuly implanted into the 11 patients, and there were 1 case of late type I endoleak, 1 of type II endoleak, 1 of iliac occlusion and 1 of death after surgery. Totaly 11 stent-graft trunks, 18 iliac stent-grafts, 1 Cuff, and 1 bare metal stent were implanted in the domestic-made stent-graft group (2.8 stents/case). Totaly 21 patients were subjected to Gore Excluder repair with the success rate of 90%, and 2 cases of intraoperative I type endoleak (10%), 2 of postoperative I type endoleak and 2 of postoperative II type endoleak were observed. Totaly 21 stent-graft trunks, 28 iliac stent-grafts and 3 Cuff were implanted in the Gore Excluder group (2.47 stents/case). These results suggest that the novel domestic-made stent-graft has achieved a satisfactory outcome in endovascular abdominal aortic aneurysm repair, showing no significant differences in related indicators with the Gore Excluder; however, the long-term outcomes stil need to be further studied.
Keywords:StentsAortic AneurysmAbdominalPostoperative ComplicationsTissue Engineering
Publication Date:2016-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:9( 7097-7105 )
Chinese Journal of Tissue Engineering Research

Chinese Journal of Tissue Engineering Research

PKUISTIC
ISSN:2095-4344
Year, Vol.(Issue):2016,20(47)