Abstract:The Cansolv exhaust treatment process was introduced for exhaust purification in a sour gas field.The combined Venturi quench tower suffered serious corrosion after commissioning,affecting the normal operation of the purification plant.In order to address the corrosion issue on site,the corrosion mechanism and major influencing factors were investigated by simulating operation conditions,theoretical analysis and on-site verification based on the process parameters.The control measures were discussed based on the major corrosion control factors,and theirs application effectiveness was evaluated.The research result showed that the tower wall was corroded by high-temperature,high-concentration sulfuric acid droplets formed through heat exchange between dilute acid mist and high-temperature flue gas,which impacted the tower wall circumferentially.Consequently,a narrow circumferential corrosive groove formed on the 254SMo high-alloy austenitic stainless steel tower wall.Improving the equipment structure by reducing the tower wall temperature through a liquid film to avoid dilute acid concentration can effectively migigate the equipment corrosion.For in-service equipment,locally lining the tower with heat-resistant and acid-resistant materials can effectively alleviate corrosion.The research results provide a reference for the design and material selection of the similar combined Venturi quench tower.
Keywords:Combined Venturi quench towerFlue gasSulfuric acidCorrosion
Publication Date:2026-02-25
Online Publishing Date:2026-11-11(First online date of this platform, not the publication date of the document)
Pages:8( 94-101 )
Natural Gas and Oil

Natural Gas and Oil

ISTIC
ISSN:1006-5539
Year, Vol.(Issue):2026,44(1)