Abstract:Objective To assess renal oxygen metabolism and iron deposition in type 2 diabetes mellitus(T2DM)patients using a combination of blood oxygen level-dependent(BOLD)and mDixon Quant techniques.Methods Clinical data of 58 T2DM patients from Tianjin First Central Hospital(September 2022-December 2023)were prospectively collected.According to urinary albumin-to-creation ratio(ACR),patients were divided into the normal albuminuria(NAU,ACR<30 mg/g,n=35)group and the microalbuminuria(MAU,30 mg/g≤ACR<300 mg/g,n=23)group.Thirty-three healthy volunteers were included as the control group during the same period.All participants underwent renal BOLD and mDixon Quant MRI to obtain cortical and medullary apparent relaxation rate(R2*)values.The differences of general data and image parameter values were compared between groups.Receiver operating characteristic(ROC)curves were used to analyze the diagnostic efficacy of relevant parameters for early renal function changes.Results There were significant differences in body weight,estimated glomerular filtration rate(eGFR)and ACR between the control group,the NAU group and the MAU group(P<0.01).The R2* value in renal cortex was lower than that in renal medulla(P<0.01)in the same group.Apart from R2* value of BOLD renal cortex,which showed no significant difference between the three groups(P<0.05),and the differences in the other parameters were statistically significant(P<0.05).When distinguishing between the control group and the NAU group,the NAU group and the MAU group,as well as between the control group and the early-stage T2DM(NAU+MAU)group,the combined two-sequence approach demonstrated higher area under the curve(AUCs)than any single sequence alone,with AUC value of 0.892(95%CI:0.809-0.975),0.785(95%CI:0.666-0.904)and 0.841(95%CI:0.756-0.926),respectively.Conclusion The combination of BOLD imaging with mDixon Quant enables noninvasive and quantitative assessment of alterations in renal oxygen metabolism and iron content in early-stage T2DM patients.The diagnostic performance of this combined approach surpasses that of individual methods.
Keywords:diabetes mellitustype 2albuminuriablood oxygenation level dependentmDixon Quantrenal oxygenationoxygen metabolismiron deposition
Publication Date:2025-11-15
Online Publishing Date:2025-11-26(First online date of this platform, not the publication date of the document)
Pages:7( 1197-1203 )
Tianjin Medical Journal

Tianjin Medical Journal

ISTIC
ISSN:0253-9896
Year, Vol.(Issue):2025,53(11)