DOI: 10.11958/20241974
The application value of ultrasound BI-RADS classification combined with serum FGFR1 and GDF3 in the differential diagnosis of benign and malignant breast masses
LI Na
HE Ying
TENG Fei
HE Wenshu
GUO Caifeng
ZHONG Na
WU Qiong
LI Jun
Abstract:Objective To explore the application value of combining the ultrasound breast imaging reporting and data system(BI-RADS)classification with serum fibroblast growth factor receptor 1(FGFR1)and growth differentiation factor 3(GDF3)in the differential diagnosis of benign and malignant breast masses.Methods A total of 159 patients with breast masses were selected and divided into the benign mass group(n=83)and the malignant mass group(n=76)based on postoperative pathological diagnosis.All patients underwent ultrasound examination,and enzyme-linked immunosorbent assay(ELISA)was applied to detect serum levels of FGFR1 and GDF3.Receiver operating characteristic(ROC)curve was applied to analyze the diagnostic value of ultrasound BI-RADS classification and serum FGFR1 and GDF3 levels for benign and malignant breast masses.Kappa test was applied to analyze the consistency between various diagnostic methods and pathological diagnosis.Results The serum levels of FGFR1 and GDF3,the proportions of irregular morphology,unclear boundaries,spiculation,microcalcifications,blood flow grade Ⅱ-Ⅲ and posterior echo attenuation,RI and PI were higher in the malignant tumor group than those in the benign tumor group(P<0.05).The area under the curve(AUC)of FGFR1,GDF3 and ultrasound BI-RADS classification in the differential diagnosis of benign and malignant breast masses separately and in combination was 0.802(95%CI:0.732-0.871),0.817(95%CI:0.751-0.884),0.848(95%CI:0.784-0.912)and 0.956(95%CI:0.918-0.993),respectively.The combined diagnosis was more effective than that of the individual diagnosis of each indicator.The consistency between the individual and combined diagnosis of benign and malignant breast masses and pathological diagnosis showed that the Kappa values were 0.517,0.514,0.688 and 0.912,respectively,with the highest consistency observed in the combined diagnosis(P<0.05).Conclusion Ultrasound BI-RADS classification combined with serum FGFR1 and GDF3 has high application value in the differential diagnosis of benign and malignant breast masses.
Keywords:breast neoplasmsultrasonographyreceptorfibroblast growth factortype 1growth differentiation factor 3diagnosisdifferentialbreast lumpbreast imaging reporting and data system
Publication Date:2025-03-15
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:5( 247-251 )
