To evaluate dynamic three-dimensional echocardiography using sequential segmental approach with STIC in diagnosis of feta ECD
KONG Xiao-yu
LU Pei-ming
Abstract:Objective To evaluate the application of STIC with segmented analytical method in the diagnosis of fetal atrial septal defect. Method Review the 6600 high-risk pregnant women who accepted PHILIPS iE33 Echocardio graphy examination in our hospital , twelve cases by two-dimensional echocardiographicas atrial septal defect then using real-time STIC method to collect data and offline playback compared with sonography after birth. Results Compared with two-dimensional gray-scale ultrasonography , in the diagnosis of fetal atrial septal defect the coincidence rate of STIC with segmented analytical method was 96.5% and 96.7% respectively , no statistically difference between them (P > 0.03). However, the operating time in STIC with segmented analytical method is shorter, and with the statistically significant (P < 0.03). Conclusion Compared with gray-scale ultrasound , STIC technique combined with segmented analytical method can obtain more valuable information and improve the diagnosis coincidence rate , which is a valuable new technology.
Keywords:Endocardical cushion defectSequential segmental approachSpatiotemporal image correlation
Publication Date:2014-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:2( 1944-1945 )