The clinical observation of 1100~1800 nm broad band infrared intense pulsed light for the treatment of periorbital wrinkle
DONG Yi-yun
ZHOU Guo-yu
Abstract:Objective To investigated the broad band infrared intense pulsed light (IPL) instrument for periorbital wrinkle. Methods 1100~1800 nm broad band infrared IPL (Titan, Cutera, Brisbane, CA) was used for periorbital wrinkle therapy of 31 chinese with modiifed Fitzpatrick wrinkle score (MFWS) 0.5-2.5. Energy range was 26~34 J/cm2, the interval was 4 weeks, 3 to 5 times as a course. Two treatment-independent evaluators conifrmed efifcacy at baseline, the last treatment, 1 and 3 months’ follow up. The patients were asked to rate the pain level during the treatment and their satisfactory by questionnaires at 3 months’ follow up. Results An average of 0.85 class and 0.75 class was achieved at 1 and 3 months follow up respectively, which had statistical difference (P<0.05). No dissatisfactory and no adverse effect was observed. 93.54%(29/31) patients rated painless during the session. Conclusion The broad band infrared IPL technology is safe and effective for periorbital wrinkle, painless is a main advantage.
Keywords:Broad band infrared IPL1100~1800 nmPeriorbital wrinkleModiifed Fitzpatrick wrinkle score
Publication Date:2014-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 370-373 )
Journal of Practical Dermatology

Journal of Practical Dermatology

ISTIC
ISSN:1674-1293
Year, Vol.(Issue):2014,(5)