Influence of continuous monitoring of flow and recirculation rate of autologous arteriovenous fistula on hemodialysis patients
Abstract:Objective:To know about the clinical significance of continuous monitoring of the flow and the recir-culation rate of the autologous arteriovenous fistula of hemodialysis patients,so as to provide a theoretical basis for the clinical management of arteriovenous fistula.Methods:A total of 72 cases of maintenance hemodialysis patients who took the autologous arteriovenous fistula as the vascular access were selected for observation for 1 2 consecutive months,and the flow and recirculation rate of these practical accesses were detected by ultrasonic di-lution technique every 3 months,consecutive detection for 3 times,and then to follow up for 6 months.During the observation period,the actual dialysis circuit (Qa),recirculation rate(AR),arteriovenous fistula flow(AF), cardiac output(CO)were recorded during the hemodialysis.Results:All the patients involved in the study,72 ca-ses completed internal fistula monitoring of the first round and second round,70 cases completed the data meas-urement in the third round.There were two cases of patients switching to central venous catheter dialysis and exiting follow up because of internal fistula occlusion.During 1 2 months of continuous monitoring,the AF val-ue of patients was 256 mL/min to 2 340 mL/min (888 mL/min±419 mL/min),5 cases of patients with AR>5% in first round,the AF value of the 5 patients was less than 500 mL/min (256 mL/min~490 mL/min),and the embolism occurred in them at the end of follow up.There was no statistically significant difference in AF value among the 3 rounds.In 72 cases of patients with arteriovenous fistula,there were 18 cases embolism oc-curred at the end of the follow up.In the 18 cases with embolism the mean AF value was 709 mL/min±337 mL/min in 3 rounds,mean AF value of 54 cases patients with no embolism was 1 171mL/min±692 mL/min;there was statistically significant difference in the AF and recirculation rate between embolism group and no thrombosis group(P<0.05).Conclusion:Continuous monitoring of flow and recirculation rate of autologous ar-teriovenous fistula had good predictive value for the risk of internal fistula embolization.It was an effective tool of early diagnosis of access dysfunction and early detection of embolism.
Keywords:hemodialysisarteriovenous fistulaembolizationultrasonic dilution technique
Publication Date:2015-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 4127-4130 )
Chinese Nursing Research

Chinese Nursing Research

PKUISTIC
ISSN:1009-6493
Year, Vol.(Issue):2015,(33)