Field Maintenance for Sliding Bearing of High Voltage Asynchronous Motor
Zhan Wang
Wu Saibiao
Abstract:Fault diagnosis of high voltage asynchronous motor bearing involves many professional knowledge, in?cluding motor ventilation structure, working principle of the sliding bearing, oil station structure and oil system, on-site installation and foundation rigidity, etc, which makes the fault causes are difficult to accurately ensure. This paper summarizes the on-site experience of motor maintenance in cement production line. Taking tempera?ture rise, vibration and oil leakage into consideration, a detailed scheme of fault handling is obtained through the?ory analysis and expounding relationships of the fault and equipment structure, site operation and maintenance. This scheme has a certain practicality.
Keywords:cementasynchronous motorsliding bearingmaintenance
Publication Date:2015-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:3( 44-46 )