Simulation and Verification of Greenhouse Soil Wall Temperature Field by FEM Analysis
Hou Jialin
Wang Tao
Jiang Tao
Wang Xiufeng
Abstract:It was significant to study the temperature gradient and its change rule for evaluation of heat prevention performance , design and construction of greenhouse wall .The temperature data of greenhouse soil wall in Taian region were measured through multi -point temperature test instrument from December 2012 to February 2013 .The measured results coincided with that obtained through ANSYS FEM simulation .The fur-ther simulation results showed that the temperature of heat release and absorption layer in the wall changed pe -riodically in a day , while that of heat preservation and insulation layer changed smaller .The temperature at the wall bottom was higher , and changed a little in the horizontal direction , which was stable at 10~14℃for long time.The temperature was the highest at the place 0.2 m away from the inner surface of wall , and re-duced gently along the direction of wall thickness; the outer surface of the wall had the lowest temperature . Based on the simulated and measured results , the optimized soil wall of greenhouse in Taian area showed that the minimum thickness should be 2.2 m, including 0~0.5 m of heat release and absorption layer and 1.3~1 .7 m of heat preservation and insulation layer .
Keywords:GreenhouseSoil wallANSYS analysisTemperature fieldTaian area
Publication Date:2014-01-01
Online Publishing Date:2026-05-22(First online date of this platform, not the publication date of the document)
Pages:6( 7-11,15 )
Shandong Agricultural Sciences

Shandong Agricultural Sciences

ISTIC
ISSN:1001-4942
Year, Vol.(Issue):2014,(4)