Determination of pd in miglitol by microWave digestion - graphite furnace atomic absorption spectrometry
SHAO Jun-ping
HAO Gui-zhou
WU Shan-xia
Abstract:Objective To establish a method for the determination of Pd in miglitol by graphite furnace atomic absorp-tion spectrometry. Methods Palladium hollow cathode lamp was used. The detection wavelength was 247. 6 nm. Graphite Furnace Atomizer was adopted. Results The linear range of Pd was 0. 0 ~ 140. 0 μg·L - 1(r = 0. 998 3),the average re-covery was 94. 4% and the RSD was 3. 5%(n = 6). Conclusion This method can be used to determine residual Pd in miglitol.
Keywords:Microwave digestionGraphite furnace atomic absorption spectrometryMiglitolPalladium
Publication Date:2014-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:2( 272-273 )
Journal of Pharmaceutical Research

Journal of Pharmaceutical Research

ISSN:2095-5375
Year, Vol.(Issue):2014,(5)