Design Calculation of Laminar Cooling High-level Water Tank and Laminar Water Flow of Strip Pass Line
ZHANG Wenxu
SHEN Tiecheng
YAN Wenbiao
LI Ting
LU Wenli
Abstract:This article studies the design calculation of laminar cooling high-level water tank and laminar water flow.Laminar cooling of hot-rolled strip steel is an important production process,controlling the cooling of hot-rolled steel plates through laminar water flow.The operation of the cooling water system is influenced by the rolling pace of strip steel and the diverse cooling requirements of steel,which may lead to production disturbances,compromised product quality,or energy waste.Therefore,accurately determining the cooling water quantity is of significant importance for cost reduction and improved production efficiency.Through theoretical analysis and calculation,this article focuses on designing the capacity of the high-level water tank to ensure stable water supply during the production process and guarantee product quality.
Keywords:strip rollinglaminar coolinghigh-level water tanktheoretical calculationengineering practice
Publication Date:2024-06-20
Online Publishing Date:2026-05-22(First online date of this platform, not the publication date of the document)
Pages:4( 46-49 )
Shandong Metallurgy

Shandong Metallurgy

ISSN:1004-4620
Year, Vol.(Issue):2024,46(3)