Analysis of the Causes of a Lightning Injury Incident in Zhongshan City
LUO Zhiyong
ZHEN Xiaoqiong
YIN Qiyuan
HUANG Yuan
WU Jingzun
LIN Shiqi
XU Jinyan
Abstract:Based on multiband radar monitoring data from Zhongshan City and Guangdong lightning positioning system data,combining model calculations,we investigated a lightning strike incident on Shitou Mountain in Zhongshan City on April 5,2024.This event,which caused transient cardiorespiratory arrest and suspended animation in one victim,occurred at the southern periphery of a convective cloud cluster during brief showers.The lightning channel featured dual-ground termination points(peak current:-20 kA)that preferentially struck two adjacent trees before side-flashing to a victim located only 0.2 m away.Calculations indicate the victim experienced both a direct strike(2.312 kA)and step voltage(348.04 kV).A witness standing 1.1 m from the tree was exposed to about 22.6 kV step voltage(below the 43.96 kV safety threshold),reporting only finger numbness.The accompanying children at 2-3 m distance experienced 3.61-7.56 kV step voltage with no effects.
Keywords:lightning strikesuspended animationthunderstorm weatherside flashstep voltage
Publication Date:2025-08-30
Online Publishing Date:2025-09-23(First online date of this platform, not the publication date of the document)
Pages:9( 476-484 )
Journal of Tropical Meteorology

Journal of Tropical Meteorology

ISTICPKUCSCD
ISSN:1004-4965
Year, Vol.(Issue):2025,41(4)