A Case of Severe Adverse Reaction Caused by Tropisetron Hydrochloride
Abstract:Patient Information: A 37-year-old female patient, weighing 73 kg, was admitted to the hospital urgently with the chief complaint of '52 days of amenorrhea, 4 days of vaginal bleeding, and 2 days of lower abdominal pain'. The admission diagnosis was 'ectopic pregnancy'. Blood pressure (BP), electrocardiogram (ECG), chest X-ray, blood routine, and biochemical tests were all normal. It was planned to perform 'laparoscopic termination of ectopic pregnancy' under general anesthesia. The patient fasted for 8 hours and had no fluids for 4 hours before the operation. After signing the informed consent, the patient entered the operating room at 10:45 on the same day and received lactated Ringer's solution. Monitoring showed BP (cuff) 143/82 mmHg, heart rate (HR) 103 beats/min, pulse oximetry saturation (SpO2) 100%, and respiratory rate (RR) 16 breaths/min.
Machine-generated Keywords:
Publication Date:2025-04-15
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:3( 161-163 )
Perioperative Safety and Quality Assurance

Perioperative Safety and Quality Assurance

ISSN:2096-2681
Year, Vol.(Issue):2025,7(2)