Experiment study on new technology of methane content measurement by dual difference
Abstract:In view of the problem that the environment in local mine is complex, which makes it difficult to extract weak methane gas signal, a new methane detection technology based on dual difference was proposed according to the principle of infrared absorption spectrum. The detection technology adopted two wavelength-two path differential detec- ting structure and got light born voltage by a kind of monochromatic light' s twice difference passing the detector with different wavelength. Then it got outputs by AD7794 chip achieving two light signals' division. Finally the concentra- tion back-in-deuced formula was obtained through the measurement of variable concentrations of the methane gas in- jected into a new kind of gas chamber with different length which was designed by Ring-down cavity. The experimental results show that adopting dual difference can extract weak methane gas signal more effectively, and solve the perturba- tion problem of light path, and get higher precision and accuracy with error equal to 1%
Keywords:dual difference detectingmethane contentspectrum absorptionRing-down cavity
Publication Date:2012-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 1161-1164 )
Journal of China Coal Society

Journal of China Coal Society

PKUISTICEI
ISSN:0253-9993
Year, Vol.(Issue):2012,37(7)