Study on reasonable determination of installing angle of isolating dust air curtain in fully-mechanized working face
SHI Shi-liang
WANG Hai-qiao
WU Zhong-li
Abstract:The hazard of the dust to the mine workers was pointed out, and the met hod protecting the mining machine driver from the dust is also described in this paper. Firstly, the districts of the air curtain was established, and then, the computer calculation of the installing angle of the isolatingdust air curtain was carried out based on the district ideas. The analysis result about the installing angle of the air curtain is below or equal to 15°.The analyzing result reduced the testing steps and cut down the engineering test costs. The industrial testing results in Gequan Coal Mine of Xingtai Mining Industry Group Ltd have proved that the analysis results in this paper are correct.
Machine-generated Keywords:
Publication Date:2001-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 164-167 )
JOURNAL OF CHINA COAL SOCIETY

JOURNAL OF CHINA COAL SOCIETY

PKUISTICEI
ISSN:0253-9993
Year, Vol.(Issue):2001,26(2)