Performance Analysis and Development of Gas Purifying Device Used in Emergency Refuge System
BO Zhige
Abstract:Aiming at problems caused by compressed air bottles or explosion-proof type battery exhausted in mine emergency refuge system which could not meet the demand for gas purifying beyond rated time,this paper designed gas purifying device on the basis of double pneumatic,electric fan series and parallel installation,the foot human drive mechanism as the main purifying drive mode was added to reduce operating rotation speed of body and save labour.By test and comparative analysis of foot human drive,electric,pneumatic modes in the state of independent working,purification performance for toxic and harmful gas was evaluated comprehensively,namely the calcium hydroxide’ s medicine layer thickness of 100~125 mm as load,under the maximum mode of exhaust air rate,volume of exhaust air reached 81. 2~102. 4 m3 during 20 min,so design objective on gas rapid purification of 20 persons emergency refuge system could be reached.
Keywords:emergency refuge systemgas purifyingbig transmission ratiohuman drive mechanismspeed up transmission device
Publication Date:2014-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:5( 69-72,64 )