Division on Fire Area in Integrated Coal Mine Based on Indicator Gases and Infrared Detection Technique
YU Shu jiang
YANG Cheng yi
XU Ji yuan
ZHU Hong qing
Abstract:According to the problem that a large number of residual coal left in the goaf of the resources integration mine because of the early extensive mining,which was easy to cause spontaneous combustion of coal.Taking No. 4+9 coal seam of Beizu Coal Mine as a study subject,the combustion situation of fire area was researched through indicator gas experiment,and the high-temperature area of the roadway roof face was divided through infrared detection technique.The result showed that,CO、C2H4 and C2H6 could be taken as the indicator gas for spontaneous combustion in No. 4+9 coal seam of Beizu Coal Mine,the temperature in fire area was 80~110 ℃,and there was a tendency that the fire area enlarged from north to south.The research result provided reference for drilling detection and plugging and so on.
Keywords:fire areaindicator gasspontaneous combustioninfrared detection techniquehigh-temperature area
Publication Date:2014-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 55-57,61 )
Coal Science and Technology

Coal Science and Technology

PKUISTIC
ISSN:0253-2336
Year, Vol.(Issue):2014,(5)