Analysis on water disaster control technology of broken surrounding rock in south return airway of Sangshuping Coal Mine
WANG Minghe
Abstract:The south return airway of Sangshuping Coal Mine is affected by the B1 anticline in the 490-512 m section of the roadway,resulting in the fragmentation of the surrounding rock and a maximum amount of water spray of 15 m3/h on the roof and sides.The de-formation of the roadway is severe,posing a serious threat to the normal use of the south return airway.Through grouting reinforcement,the amount of water spray into the roadway in this section was reduced to 0.2 m3/h,and the roadway was almost stable,indicating that grouting reinforcement of the surrounding rock fracture zone of the roadway and sealing of the water-conducting fracture had obvious effects,pointing out the direction for the prevention and control of water in the roadway through the fracture zone area.
Keywords:anticlinefracture zonegrouting reinforcementwater control