Reliability analysis of traction unit of electrical haulage shearer
GE Hongbing
Abstract:For the problem that traditional manual reliability analysis method for traction unit of electrical haulage shearer could not find hidden fault real-timely,a reliability analysis method of traction unit of electrical haulage shearer was proposed which was based on fault tree analysis and fuzzy logic theory.Non-traction fault tree of the traction unit is built firstly,and failure degree of basic events in the fault tree is graded.Then membership degree of each basic event belonging to corresponding fault grade is calculated by use of fuzzy synthetic discrimination method,so as to get the fault form and fault rate of the traction unit in each working stage.The method can realize reliability analysis and health management of the traction unit of electrical haulage shearer.
Keywords:coal miningelectrical haulage shearertraction unitnon-traction faultreliability analysisfault treebasic eventfuzzy logic theory
Publication Date:2018-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:6( 51-56 )
Industry and Mine Automation

Industry and Mine Automation

PKUISTIC
ISSN:1671-251X
Year, Vol.(Issue):2018,44(4)