Design of novel intrinsically safe power supply with "ia" grade
YU Zhixue
FANG Xupeng
ZHAO Yang
Abstract:According to working condition of mine-used power supply in coal mine underground,novel intrinsically safe power supply with "ia" grade was designed.The power supply uses a fully enclosed ACDC module to eliminate special flameproof enclosure,and has over-voltage protection circuit of dual redundancy and over-current protection circuit of three redundancy.The experimental results show there is no spark when the power supply load is short circuited under the conditions of no fault,one counting fault and two counting faults,which realizes intrinsic safety.
Keywords:mine-used power supplyintrinsic safety type" ia" protection gradeover-voltage protection of dual redundancyover-current protection of three redundancy
Publication Date:2017-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 83-86 )
Industry and Mine Automation

Industry and Mine Automation

PKUISTIC
ISSN:1671-251X
Year, Vol.(Issue):2017,43(8)