Simulation and Analysis of Three-phase Four-wire Four-leg APF with Deadbeat Control
ZHANG Dong-liang
LI Gang
WANG Song
JI Jian-ping
Abstract:In the paper, three-phase four-wire four-leg APF was taken as study object, the ip-iq method was chosen to detect harmonic current, and the method of deadbeat control with full-digitalization was adopted in tracking link of order current.The Matlab/Simulink simulation results showed that the active filter system with deadbeat control method can compensate harmonic current well and inhibit neutral current effectively.
Keywords:active filterAPFthree-phase four-wire systemfour-legdeadbeat controlsimulation
Publication Date:2009-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 55-58 )
INDUSTRY AND MINE AUTOMATION

INDUSTRY AND MINE AUTOMATION

PKUISTIC
ISSN:1671-251X
Year, Vol.(Issue):2009,35(8)