Imaging Characteristics Analysis and Misdiagnosis Cause of Research of Ultrasound in the Treatment of Thyroid Mi-crocarcinoma
HU Fu-chang
XIE Xue-mei
XU Hong-tao
Abstract:Objective To evaluate the imaging characteristics analysis and cause of misdiagnosis of ultrasound in the treatment of TMC. Methods 60 patients with TMC ( observation group) and 60 patients with benign and malignant thyroid lesions ( control group) were included in this study. Based on the sequence of enrollment and the patients were divided into two groups:experiential group (60 patients) receiving computed tomography and high-frequency ultrasound and control group (60 patients) receiving high-frequency ultrasound. The diagnosis function parameters were observed and compared. Results The rate of diagnostic accordance of CT scanning in observation group was 76. 67%;and misdiagnosis and missed diagnosis rates were 11. 67%. The accordance rate of the high-frequency ultrasound was 93. 33%;misdiagnosis rate and missed diagno-sis rate were 6. 67% and 0 with significant difference (P<0. 05). There was statistically significant difference between the le-sions numbers, morphology, boundary, echo and calcification in the diagnosis with high frequency ultrasound in the two groups (P<0. 05). Conclusion Ultrasound diagnosis has special effect in the treatment of TMC by evaluating the analysis of imaging characteristics and misdiagnosis cause.
Keywords:Thyroid NeoplasmUltrasonographyTomographyX-Ray ComputedMisdiagnosis
Publication Date:2014-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:3( 39-41 )