Causes of and precautions against cricoarytenoid joint dislocation caused by endotracheal intubation
WANG Dong
GUO Rui
XUE Xiaodong
Abstract:Objective To investigate the etiological factors of and precautions against cricoarytenoid joint dislocation after endotracheal cannulation and extubation in general anaesthesia patients.Methods The clinical data on three cases of cricoarytenoid joint dislocation after endotracheal intubation treated between January 2015 and December 2016 was summarized. The causes of dislocation were analyzed retrospectively.Results All three the postoperative patients extubated in the ICU had the right front dislocation, whose reposition surgeries were completed within three weeks. The causes of dislocation were probably associated with the timing of extubation, standing position of doctors during extubation, site and pressure of balloons and placement of stomach tubes.Conclusion An intimate knowledge of the possible causes of cricoarytenoid joint dislocation is conducive to precautions and treatment.
Keywords:cricoarytenoid joint dislocationendotracheal intubationtiming of extubationetiological analysisprecaution
Publication Date:2017-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:3( 405-406,409 )