Abstract:ObjectiveTo introduce the effectiveness of the direct ophthalmoscope transillumination method for the screening identification of the eyes after orthokeratology and refractive corrected eye after posterior chamber ICL implantation (ICL implanted eye) and to analyze the mechanism of this technology.MethodsHandheld ophthalmoscope was used to transilluminate positive and the side in the pupil areas. In the background of reflective orange, the pupil areas were observed for the specific shadow occurrence. The shadow imaging was saved using the hole camera.ResultsThere were 181 cases of orthokeratology and 7 cases of ICL implant.ConclusionThe method of the ophthalmoscope transillumination is a thorough way to accurately detect orthokeratology and ICL implanted eyes. Because it is sensitive, specific, convenient and efficient, it is suitable for the population screening of student pilots and other military personnel.
Keywords:Personnel selectionPhysical examinationOrthokeratologyLens implantation