Analysis and management of 61 cases of incompatible cross-matching
FAN Feng-yan
QI Shu-yuan
XIONG Mei
WEIS hao-ping
ZHOU Jing
LIU Juan
WANG Hong-bo
Abstract:Objective To explore measures for incompatible cross-matching by analyzing 61 cases of incompatible cross-matching. Methods Samples with incompatible cross-matching in recent 2 years in our hospital were tested with blood grouping,unexpected antibody identification and serological tests of store blood. Tests of cross-matching based causes of inconformity of cross-matching were performed. Whether there was significant difference between ratio of anti-E in our test and reported 22/37 was analyzed. Results Several causes were found can induce inconformity of cross-matching. The amount of causes of incompatible cross-matching found among 61 cases were:artificial causation 11,unconformity of forward and reverse ABO blood grouping 11,disqualification of store blood 17,allo-antibody 17,auto-antibody 5. There was no significant difference between ratio of anti-E in our test and reported 12/17. No blood transfusion reactions were observed among 61 cases after compatible stored blood transfusion. Conclusion Analysis and management of causes for inconformity of cross-matching can ensure compatibility of stored blood and transfusion safety.
Keywords:Cross-matchingIncompatibility
Publication Date:2013-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:3( 152-154 )