Abstract:In order to optimize the protection of reinforcing bar in concrete structure,the smart systems,including the sodium nitrite(NaNO2)/ethyl cellulose(EC) microcapsule system and the sodium monofluorophosphate(MFP)/ethyl cellulose(EC) microcapsule system,were designed and studied.XCT(X-ray computed microtomography) testing technology was used to trace the corrosion process and introduced to test the corrosion inhibition effect.The results show that the smart system has a very significant corrosion inhibition performance.Compared with the blank group in wet-dry cycle tests,sodium nitrite system and sodium monofluorophosphate system significantly delay initial corrosion period for 648 and 216 h,and the initial cracking period is also prolonged for 432 and 144 h,respectively.After 648 h of wet-dry cycle,the corrosion ratio of the sodium nitrite system is only 1.93%,and the sodium system is 3.06%,which is much lower than that of blank system's 10.46%.