Analysis of new standard on heating seasonal performance factor for the variable frequency air conditioner in North America
ZOU Dashu
SHAO Yanpo
HUANG Rupu
HUANG Dong
Abstract:With the energy efficiency upgrade of AHRI 210/240 in the United States,the calculation method of heating seasonal performance factor(HSPF2)of variable frequency air conditioners focuses more on the medium and low temperature conditions.Through the analysis on the calculation method of HSPF2 and experimental data,it is found that under the same configuration,the HSPF2 is significantly lower compared with the original heating seasonal performance factor(HSPF).The HSPF2IV corresponding to the climate zone IV decreases by 8.0%on average,and the HSPF2V corresponding to the zone V decreases by 17.2%on average.The COP under medium and low temperature conditions(H2V,H32,H42)has a large proportion of influence on HSPF2.In product design,increasing compressor capacity,using efficient compressor and motor,optimizing heat exchanger structure and other solutions can be considered to improve the seasonal performance factor.
Keywords:Variable frequency air conditionerHeating seasonal performance factorAHRI 210/240
Publication Date:2024-12-28
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 18-20,62 )