A High Accuracy Calibration Method of Picoampere and Nanoampere DC Current
WANG Yibang
ZHENG Shiqi
WU Aihua
FU Shaohui
Abstract:A high accurate calibration method is proposed aiming at the problem of metrology of commercial picoampere and nanoampere DC current .The method covers the development of active DC current adapter and the establishment of volt‐age pick‐up model of high standard resistor ,then obtains the current by ohm's law .The result of verification set based on a‐bove demonstrates that ,it is convenient ,simple ,and applicable to picoampere and nanoampere DC current of any kind and most commercial grade .
Keywords:picoampere and nanoampere DC currentactive DC current adaptervoltage of high standard resistor
Publication Date:2015-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:3( 44-46 )
Computer and Digital Engineering

Computer and Digital Engineering

ISTIC
ISSN:1672-9722
Year, Vol.(Issue):2015,(1)