Discussion on Temperature Rise Test Method for Power Adapters
LI Wenye
Abstract:This article discusses the temperature rise testing method for power adapters and examines the impact of natural and forced convection environments on the test results.The results indicate that in a forced convection environment,the surface temperature rise is over 40%lower than in a natural convection environment.This difference also leads to variations in temperature rise of more than 9%and 24%for the internal power switch and electrolytic capacitor,respectively,with maximum differences reaching 30%and 33%.The natural convection environment is closer to actual usage conditions and is more suitable for temperature rise testing.
Keywords:power adaptertemperature rise testtesting environmentconvection
Publication Date:2026-07-30
Online Publishing Date:2026-11-18(First online date of this platform, not the publication date of the document)
Pages:4( 156-158,163 )
Metrology & Measurement Technique

Metrology & Measurement Technique

ISSN:1004-6941
Year, Vol.(Issue):2026,52(7)