Error Analysis Modeling and Parameter Optimization for 3D Localization of Nuclear Facilities Based on Dual Light Field Intersection Imaging
YUE Shiqiang
XU Jin'gang
Abstract:Aiming at the actual needs of non-contact three-dimensional positioning of nuclear facilities components in the radiation environment of the nuclear industry,in order to improve the measurement accuracy and engineering practicability of dual field intersec-tion imaging technology in the monitoring of nuclear facilities,and solve the problems of inaccessible personnel and failure of traditional optical means in the radiation environment,this paper establishes a three-dimensional positioning error calculation model of dual field intersection imaging,analyzes the influence of key parameters on the positioning error,and determines the optimal value range of each parameter combined with the on-site working conditions of nuclear facilities.The experimental results show that when the camera base-line spacing is(2~3)m,the installation angle is 40°~45°,the refocusing coefficient is 0.2~0.3,and the optical axis angle of the microlens is≤45°,the three-dimensional positioning error of the system can be controlled within 12mm,which meets the accuracy requirements of component positioning and equipment deformation monitoring of nuclear facilities.
Keywords:nuclear facility monitoringdual light field intersection imagingnon-contact measurementerror analysisparameter opti-mization
Publication Date:2026-07-30
Online Publishing Date:2026-11-18(First online date of this platform, not the publication date of the document)
Pages:4( 68-71 )